Effectiveness of a laboratory-scale vertical tower static chamber steam pasterurization unit against Escherichia coli 0157:H7, salmonella typhimurium, and listera innocua on prerigor beef tissue

dc.citation.epage1633en_US
dc.citation.issn0362-028Xen_US
dc.citation.issue8en_US
dc.citation.jtitleJournal of food protectionen_US
dc.citation.spage1630en_US
dc.citation.volume67en_US
dc.contributor.authorRetzlaff, Deanna D.en_US
dc.contributor.authorPhebus, Randall K.en_US
dc.contributor.authorNutsch, Abbey L.en_US
dc.contributor.authorRiemann, Jamesen_US
dc.contributor.authorKastner, Curtis L.en_US
dc.contributor.authorMarsden, James L.en_US
dc.contributor.authoreidretzlaff
dc.contributor.authoreidphebus
dc.contributor.authoreidckastner
dc.contributor.authoreidanutsch
dc.date.accessioned2008-03-28T01:45:51Z
dc.date.available2008-03-28T01:45:51Z
dc.date.issued2008-03-28T01:45:51Z
dc.date.published2004en_US
dc.description.abstractA laboratory-scale vertical tower steam pasteurization unit was evaluated to determine the antimicrobial effectiveness of different exposure times (0, 3, 6, 12, and 15 s) and steam chamber temperatures (82.2, 87.8, 93.3, and 98.9°C) against pathogens (Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria innocua) inoculated onto prerigor beef tissue. Samples were collected and microbiologically analyzed immediately before and after steam treatment to quantify the effectiveness of each time-temperature combination. The 0-s exposure at all chamber temperatures (cold water spray only, no steam treatment) was the experimental control and provided 0.3 log CFU/cm2 reductions. Chamber temperatures of 82.2 and 87.8°C were ineffective (P > 0.05) at all exposure times. At 93.3°C, significant reductions (> 1.0 log CFU/cm2) were observed at exposure times of 6 s, with 15 s providing approximately 1 log cycle greater reductions than 12 s of exposure. The 98.9°C treatment was consistently the most effective, with exposure times of 9 s resulting in >3.5 log CFU/cm2 reductions for all pathogens.en_US
dc.identifier.urihttp://hdl.handle.net/2097/582
dc.rightsReprinted with permission from the Journal of food protection. Copyright held by the International Association for Food Protection, Des Moines, Iowa, U.S.A.en_US
dc.subjectBeefen_US
dc.subjectPasteurizationen_US
dc.subjectDecontaminationen_US
dc.subjectSteamen_US
dc.subjectE. colien_US
dc.subjectSalmonellaen_US
dc.titleEffectiveness of a laboratory-scale vertical tower static chamber steam pasterurization unit against Escherichia coli 0157:H7, salmonella typhimurium, and listera innocua on prerigor beef tissueen_US
dc.typeArticle (publisher version)en_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RetzlaffJFP2004.pdf
Size:
63.43 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Plain Text
Description: