Prediction of temperature distributions in peaked, leveled and inverted cone grain mass configurations during aeration of corn

dc.citation.epage692en_US
dc.citation.issue5en_US
dc.citation.jtitleApplied Engineering in Agricultureen_US
dc.citation.spage685en_US
dc.citation.volume28en_US
dc.contributor.authorLawrence, J.
dc.contributor.authorMaier, Dirk E.
dc.contributor.authoreiddmaieren_US
dc.date.accessioned2012-12-28T19:56:19Z
dc.date.available2012-12-28T19:56:19Z
dc.date.issued2012-12-28
dc.date.published2012en_US
dc.description.abstractThree-dimensional heat and momentum transfer for the peaked, leveled, and inverted cone grain mass configurations in a corn silo was studied with aeration airflow rate ranged from 0.26 to 0.31 m³/min-t (0.24 to 0.28 cfm/bu) using the 3D finite element stored grain ecosystem model. Non-uniform airflow models for peaked, leveled, and inverted cone grain mass configurations were developed using the finite volume method. Airflow resistance due to porous media of grain material was implemented using Ergun’s equation and a linear porosity variation with low porosity at the center and maximum at the side. The velocity profile and heat transfer during aeration were quantified for the peaked, leveled and inverted cone grain mass configurations. The change in grain temperature in the inverted cone grain mass configuration was the fastest followed by the leveled and peaked configurations. It took 102, 114, and 186 h, respectively, for cored, leveled, and peaked grain mass configurations to cool the grain from 40°C to below 20°C. For the peaked cone volume, the model predicted an 84-h delay in the cooling front movement (or about 55%) compared to the inverted cone configuration. This has significant implications with respect to fan run time hours, electricity consumption, and the potential for grain spoilage.en_US
dc.identifier.urihttp://hdl.handle.net/2097/15191
dc.language.isoen_USen_US
dc.relation.urihttp://elibrary.asabe.org/azdez.asp?JID=3&AID=42419&CID=aeaj2012&v=28&i=5&T=1&redirType=en_US
dc.rights© 2012 American Society of Agricultural and Biological Engineersen_US
dc.subjectNon-uniform airflowen_US
dc.subjectAerationen_US
dc.subjectPeakeden_US
dc.subjectLeveleden_US
dc.subjectCoreden_US
dc.subjectGrain mass configurationsen_US
dc.subjectFinite volume methoden_US
dc.subjectFinite element methoden_US
dc.titlePrediction of temperature distributions in peaked, leveled and inverted cone grain mass configurations during aeration of cornen_US
dc.typeArticle (publisher version)en_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Prediction of temperature - publisher's PDF.pdf
Size:
686.84 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: