Measuring emission rates of particulate matter from fan ventilated swine barns

dc.citation.epage174en_US
dc.citation.spage169en_US
dc.contributor.authorPredicala, B.Z.
dc.contributor.authorMaghirang, Ronaldo G.
dc.contributor.authoreidrmaghiren_US
dc.date.accessioned2010-02-11T22:35:34Z
dc.date.available2010-02-11T22:35:34Z
dc.date.issued2010-02-11T22:35:34Z
dc.date.published2002en_US
dc.description.abstractMethods for measuring concentrations and emission rates of particulate matter (PM) from mechanically ventilated livestock buildings were evaluated in a laboratory facility and in a swine-finishing barn. Concentrations of PM were measured inside the room (room sampling) and at the exhaust duct (exhaust sampling). Concentrations at the exhaust duct were determined using high-volume traverse downstream of the exhaust fan, low-volume traverse downstream of the fan, and fixed sampling upstream and downstream of the fan. The traverse methods, which served as the reference, were conducted under isokinetic conditions; fixed sampling was done under both isokinetic and sub-isokinetic conditions. Compared to the traverse method, both room sampling and exhaust sampling under subisokinetic conditions overestimated PM concentrations. Fixed sampling under isokinetic conditions, on the other hand, did not differ significantly (P>0.05) from the high-volume traverse method. Thus, isokinetic fixed sampling can be an alternative to the more expensive and time-consuming high-volume PM traverse method to measure PM concentrations and emission rates at the exhaust.en_US
dc.description.conferenceSwine Day, Manhattan, KS, November 14, 2002en_US
dc.identifier.urihttp://hdl.handle.net/2097/2550
dc.publisherKansas State University. Agricultural Experiment Station and Cooperative Extension Serviceen_US
dc.relation.isPartOfSwine day, 2002en_US
dc.relation.isPartOfKansas Agricultural Experiment Station contribution; no. 03-120-Sen_US
dc.relation.isPartOfReport of progress (Kansas State University. Agricultural Experiment Station and Cooperative Extension Service); 897en_US
dc.subjectSwineen_US
dc.subjectAir qualityen_US
dc.subjectDusten_US
dc.subjectEmissionen_US
dc.subjectMeasurementen_US
dc.titleMeasuring emission rates of particulate matter from fan ventilated swine barnsen_US
dc.typeConference paperen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Swine02pg169-174.pdf
Size:
170.76 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections