Evaluation of a rotating drum mixer

Date

2010-04-08T20:00:11Z

Journal Title

Journal ISSN

Volume Title

Publisher

Kansas State University. Agricultural Experiment Station and Cooperative Extension Service

Abstract

A "rotating drum" type mixer was tested to determine if it could produce a uniformly mixed feed. Feed was manufactured in four separate trials, which examined addition sequence, mixing time, mixer capacity, and liquid addition. Uniformly mixed feed was obtained after 8 min, when ingredients were properly sequenced and mixed. Smaller batch sizes decreased the time required to obtain a uniform mixture. The mixer distributed liquid uniformly through the feed and had excellent clean-out capabilities.

Description

Keywords

Swine, Rotating drum mixer, Feed uniformity, Feed manufacturing, Mixer testing

Citation