Effects of salt particle size and sample preparation on results of mixer-efficiency testing

K-REx Repository

Show simple item record

dc.contributor.author Groesbeck, C.N.
dc.contributor.author Goodband, Robert D.
dc.contributor.author Tokach, Michael D.
dc.contributor.author Nelssen, Jim L.
dc.contributor.author DeRouchey, Joel M.
dc.contributor.author Dritz, Steven S.
dc.date.accessioned 2009-10-20T20:12:43Z
dc.date.available 2009-10-20T20:12:43Z
dc.date.issued 2009-10-20T20:12:43Z
dc.identifier.uri http://hdl.handle.net/2097/1909
dc.description.abstract Two experiments were conducted to evaluate the effects of using salt with different particle sizes and of using different samplepreparation methods on mixer-efficiency testing (time required to achieve a coefficient of variation (CV) of 10% or less among 10 feed samples). A 3000-lb capacity horizontal ribbon mixer was used to mix batches of feed. Ten samples were collected at eight times during mixing (0.0, 0.5, 1.0, 2.0, 3.5, 5.5, 8.0, and 10.5 min) after all ingredients were added from pre-determined locations in the mixer. Coefficient of variation was used to measure mixer efficiency by analysis for chloride concentration in each sample with Quantab® chloride titrators. In Exp. 1, four 3000-lb batches of feed were prepared, two with 440- micron salt and two with 730-micron salt. Samples were analyzed as collected (unground; approximately 700 microns) or were ground with a coffee grinder (ground; approximately 400 microns). A salt particle size × sample preparation × mixing time interaction (P<0.001) was observed, but a CV of 10% or less was never achieved, indicating inadequate mixing. In Exp. 2, all samples were collected from 2000-lb batches of feed made in the 3000-lb-capacity mixer. Four different salt particle sizes (440, 730, 1999, and 3000 micron) were used, and each set of samples collected was also analyzed as unground or ground. A salt particle size × sample preparation × mixing time interaction (P<0.04) was observed. As salt particle size decreased and mixing time increased, there was a decrease in CV. Grinding samples before analysis decreased CV, compared with that of the unground samples, but to a greater extent with coarse salt than with fine salt. The batch mixed with 440-micron salt and the batch mixed with 730-micron salt (ground) reached a CV of less than 10%, indicating a uniform mixture. No other treatments reached a CV of 10% or less. When the mixer was filled to the rated capacity we were unable to achieve an acceptable CV for mixer efficiency; therefore, it is important to test mixers at various fill levels. Our study also showed that it is important to use a fine mixing salt when testing mixers for mixer efficiency. en_US
dc.publisher Kansas State University. Agricultural Experiment Station and Cooperative Extension Service en_US
dc.relation.isPartOf Swine day, 2004 en_US
dc.relation.isPartOf Report of progress (Kansas State University. Agricultural Experiment Station and Cooperative Extension Service); 940 en_US
dc.relation.isPartOf Kansas Agricultural Experiment Station contribution ; no. 05-113-S en_US
dc.subject Swine en_US
dc.subject Mixer efficiency en_US
dc.subject Particle size en_US
dc.subject Pigs en_US
dc.subject Salt en_US
dc.title Effects of salt particle size and sample preparation on results of mixer-efficiency testing en_US
dc.type Conference paper en_US
dc.date.published 2004 en_US
dc.citation.epage 181 en_US
dc.citation.spage 177 en_US
dc.description.conference Swine Day, 2004, Kansas State University, Manhattan, KS, 2004 en_US
dc.contributor.authoreid goodband en_US
dc.contributor.authoreid mtokach en_US
dc.contributor.authoreid dritz en_US
dc.contributor.authoreid jnelssen en_US
dc.contributor.authoreid jderouch en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search K-REx


Browse

My Account

Statistics








Center for the

Advancement of Digital

Scholarship

cads@k-state.edu