Combined Transverse Steel-External FRP Confinement Model for Rectangular Reinforced Concrete Columns

dc.citation.doi10.3390/fib4010008
dc.citation.issn2079-6439
dc.citation.issue1
dc.citation.jtitleFibers
dc.citation.spage25
dc.citation.volume4
dc.contributor.authorAl-Rahmani, A.
dc.contributor.authorRasheed, Hayder A.
dc.contributor.authoreidhayder
dc.date.accessioned2016-09-20T17:29:24Z
dc.date.available2016-09-20T17:29:24Z
dc.date.issued2016-02-06
dc.date.published2016
dc.descriptionCitation: Al-Rahmani, A., & Rasheed, H. (2016). Combined Transverse Steel-External FRP Confinement Model for Rectangular Reinforced Concrete Columns. Fibers, 4(1), 25. doi:10.3390/fib4010008
dc.description.abstractRecently, the need to increase the strength of reinforced concrete members has become a subject that civil engineers are interested in tackling. Of the many proposed solutions, fiber-reinforced polymer (FRP) materials have attracted attention due to their superior properties, such as high strength-to-weight ratio, high energy absorption and excellent corrosion resistance. FRP wrapping of concrete columns is done to enhance the ultimate strength due to the confinement effect, which is normally induced by steel ties. The existence of the two confinement systems changes the nature of the problem, thus necessitating specialized nonlinear analysis to obtain the column's ultimate capacity. Existing research focused on a single confinement system. Furthermore, very limited research on rectangular sections was found in the literature. In this work, a model to estimate the combined behavior of the two systems in rectangular columns is proposed. The calculation of the effective lateral pressure is based on the Lam and Teng model and the Mander model for FRP wraps and steel ties, respectively. The model then generates stress-strain diagrams for both the concrete core and the cover. The model was developed for the analysis in extreme load events, where all possible contributions to the column's ultimate capacity should be accounted for without any margin of safety. The model was validated against experiments, and the results obtained showed good agreement with almost all of the available experimental data.
dc.description.versionArticle: Version of Record
dc.identifier.urihttp://hdl.handle.net/2097/33991
dc.relation.urihttps://doi.org/10.3390/fib4010008
dc.rightsAttribution 4.0 International (CC BY 4.0)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectRectangular Concrete Columns
dc.subjectFiber-Reinforced Polymer
dc.subjectConfinement
dc.subjectMaterials Science
dc.titleCombined Transverse Steel-External FRP Confinement Model for Rectangular Reinforced Concrete Columns
dc.typeText

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
fibers-04-00008.pdf
Size:
2.89 MB
Format:
Adobe Portable Document Format