Application and evaluation of short-term emergency ratings for double-circuit transmission lines

dc.citation.doi10.1080/15325008.2012.658598en_US
dc.citation.epage740en_US
dc.citation.issue7en_US
dc.citation.jtitleElectric Power Components and Systemsen_US
dc.citation.spage729en_US
dc.citation.volume40en_US
dc.contributor.authorKim, S. D.
dc.contributor.authorKim, S. R.
dc.contributor.authorMorcos, Medhat M.
dc.contributor.authoreidmorcosen_US
dc.date.accessioned2012-06-26T18:00:35Z
dc.date.available2012-06-26T18:00:35Z
dc.date.issued2012-04-27
dc.date.published2012en_US
dc.description.abstractEmergency ratings have been introduced for operating transmission lines safely and supplying current capacity efficiently, as well as controlling load flow when occurring line faults. In this paper, short-term emergency ratings are calculated by using thermal equilibrium equation for bared conductors in double-circuit transmission lines. Overhead transmission lines installed in double-circuit have been extensively utilized worldwide to enhance power transmission. Such lines show various advantages in increasing transmission capacity and decreasing power loss as well as being operated flexibly during a contingency. Even when a fault occurs in one circuit, the healthy circuit can supply power continuously during emergency without outage. The utilization of such double-circuit transmission lines during normal and/or emergency operations is described. Maximum normal operating current based on fault duration, maximum allowable temperature of conductor, and thermal line ratings are evaluated. Several performances of dip/clearance affecting short-term emergency rating are also presented.en_US
dc.description.versionArticle (author version)
dc.identifier.urihttp://hdl.handle.net/2097/13955
dc.relation.urihttp://doi.org/10.1080/15325008.2012.658598en_US
dc.rightsThis Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).en_US
dc.rights.urihttps://rightsstatements.org/page/InC/1.0/
dc.subjectDouble-circuit transmission linesen_US
dc.subjectShort-term emergency ratingen_US
dc.subjectThermal line ratingen_US
dc.titleApplication and evaluation of short-term emergency ratings for double-circuit transmission linesen_US
dc.typeTexten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Morcos ElecPowCompSys 2012.pdf
Size:
378.12 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: