High resolution wireless body area network with statistically synchronized sensor data for tracking pulse wave velocity

dc.citation.doi10.1109/EMBC.2012.6345853en_US
dc.citation.epage2083en_US
dc.citation.issn1557-170Xen_US
dc.citation.spage2080en_US
dc.contributor.authorLi, Kejia
dc.contributor.authorWarren, Steven
dc.contributor.authoreidswarrenen_US
dc.contributor.authoreidkejialien_US
dc.date.accessioned2013-09-18T17:58:11Z
dc.date.available2013-09-18T17:58:11Z
dc.date.issued2013-09-18
dc.date.published2012en_US
dc.description.abstractWireless body area networks (WBANs) will take on more diverse forms in terms of their sensor combinations and communication protocols as their presence is extended to a greater number of monitoring scenarios. This paper presents an application layer protocol that solves issues caused by sensor nodes that must compete for high speed, real-time communication with the receiver. Such applications emphasize the delivery of large amounts of raw data from different sensor nodes in a time-synchronized manner, rather than channels that experience intermittent operation. An example of tracking pulse wave velocity (PWV) is introduced in this paper, where high-precision PWVs are estimated with the help of timeline recovery and feature extraction processes in MATLAB.en_US
dc.description.conferenceEngineering in Medicine and Biology Society (EMBC), Annual International Conference of the IEEE (34th, 2012, San Diego, CA)en_US
dc.description.versionArticle: Version of Record
dc.identifier.urihttp://hdl.handle.net/2097/16467
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.relation.urihttp://doi.org/10.1109/EMBC.2012.6345853en_US
dc.rightsThis Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
dc.rights.urihttps://rightsstatements.org/page/InC/1.0/
dc.subjectPhotoplethysmogramen_US
dc.subjectPulse wave velocityen_US
dc.subjectStatistical synchronizationen_US
dc.subjectWireless body area networken_US
dc.titleHigh resolution wireless body area network with statistically synchronized sensor data for tracking pulse wave velocityen_US
dc.typeTexten_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
WarrenEMBC2012.pdf
Size:
550.18 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: