Electrical resistivity measurements of mechanically stabilized earth retaining wall backfill

dc.contributor.authorSnapp, Michael Andrewen_US
dc.date.accessioned2015-07-08T13:18:26Z
dc.date.available2015-07-08T13:18:26Z
dc.date.graduationmonthAugusten_US
dc.date.issued2015-08-01en_US
dc.date.published2015en_US
dc.description.abstractIn Kansas, mechanically stabilized earth (MSE) retaining walls are typically backfilled with coarse aggregate. Current backfill material testing procedures used by the Kansas Department of Transportation (KDOT) utilize on-site observations for construction quality assurance and the American Association of State Highway and Transportation Officials standard T 288-12 (“Standard Method of Test for Determining Minimum Laboratory Soil Resistivity”). AASHTO T 288-12 is designed to test a soil sample’s electrical resistivity (ER) that correlates to its corrosion potential. However, the test, based on material passing through a No. 10 sieve, is inappropriate for coarse aggregate typically used by KDOT as the aggregate will be retained on a No. 10 sieve and potentially leads to over-conservative designs. However, ER imaging provides a two-dimensional (2D) profile of bulk ER of backfill material, thereby yielding more information regarding backfill uniformity compared to traditional sampling. The objective of this study was to characterize bulk ER of in-place MSE wall backfill aggregate. In this study, MSE walls selected by KDOT were tested using ER imaging during construction to determine bulk ER of the backfill. Variations within backfill ER may be a result of varying aggregate material, inclusions of fines, thoroughness of compaction, and the presence of water. ER imaging was used on five walls: four MSE walls and one gravity retaining wall that contained no reinforcement. One MSE wall contained metal reinforcement, while the other four walls contained geosynthetic. The ER imaging field method produced a 2D profile that depicted ER uniformity for bulk analysis. A post processing algorithm was generated to remove the subjective nature of the ER imaging results. The program determines the bulk ER based upon the ER imaging results. These results indicate that the laboratory analysis of AASHTO T 288-12 under-estimates the bulk ER of in-situ backfill material. Identification of a material’s bulk ER will help characterize the ER of aggregates in a complementary KDOT project. Results of this study will be used to recommend an in-situ test method for aggregate used by KDOT.en_US
dc.description.advisorStacey Kuleszaen_US
dc.description.degreeMaster of Scienceen_US
dc.description.departmentDepartment of Civil Engineeringen_US
dc.description.levelMastersen_US
dc.description.sponsorshipKansas Department of Transportation Kansas State University Civil Engineeringen_US
dc.identifier.urihttp://hdl.handle.net/2097/19771
dc.language.isoen_USen_US
dc.publisherKansas State Universityen
dc.subjectElectrical Resistivityen_US
dc.subjectMechanically Stabilized Earth Retaining Wallsen_US
dc.subjectCoarse Aggregate Backfillen_US
dc.subject.umiCivil Engineering (0543)en_US
dc.subject.umiEngineering (0537)en_US
dc.subject.umiGeological engineering (0466)en_US
dc.subject.umiGeophysical engineering (0467)en_US
dc.subject.umiGeophysics (0373)en_US
dc.titleElectrical resistivity measurements of mechanically stabilized earth retaining wall backfillen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MichaelSnapp2015.pdf
Size:
7.92 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: