Study of the risk of frostbite in humans with the help of a transient 3D finger model

dc.contributor.authorManda, Prudhvi Krishna Venkatesh
dc.date.accessioned2013-07-24T12:54:33Z
dc.date.available2013-07-24T12:54:33Z
dc.date.graduationmonthAugust
dc.date.issued2013-07-24
dc.date.published2013
dc.description.abstractA new three dimensional transient human finger model was developed to predict the risk of frostbite in humans at different environmental conditions. The shape of the finger model was similar to that of a real human finger. Finite Element Techniques were used to build the finger model. Smith’s Model (1991) energy balance equations were used to calculate the temperatures in the current finger model. The current 3D finger model was validated against the experimental data of Wilson (1976) and Santee (1990). The model agreed well with the Wilson experiments and with the cold test in Santee experiments. The comparison indicates that the current finger model can be used to adequately predict the human finger responses in different environments. The current finger model was then tested in temperatures of 0, -10, -20, -25 and -30 oC and with different airspeeds 0, 3 and 6.8 m/s to assess the risk of frostbite in humans. Three resistances 0, 0.4 and 0.8 clo were used on the finger model to obtain responses in different environmental conditions. From the experimental results, an expression for safe glove resistance required to prevent frostbite in known temperatures was calculated. Also, the temperatures up to which a glove with known thermal resistance value can protect a human finger from frostbite was also computed.
dc.description.advisorSteve Eckels
dc.description.degreeMaster of Science
dc.description.departmentDepartment of Mechanical and Nuclear Engineering
dc.description.levelMasters
dc.identifier.urihttp://hdl.handle.net/2097/15995
dc.language.isoen_US
dc.publisherKansas State University
dc.rights© the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectFrostbite
dc.subjectHuman finger
dc.subjectFinite element
dc.subject.umiMechanical Engineering (0548)
dc.subject.umiPhysiology (0719)
dc.titleStudy of the risk of frostbite in humans with the help of a transient 3D finger model
dc.typeThesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
PrudhviManda2013.pdf
Size:
1.61 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: