Comparison of Synovex-S® and steer-oid® in finishing yearling steers
Date
2010-11-02
Journal Title
Journal ISSN
Volume Title
Publisher
Kansas State University. Agricultural Experiment Station and Cooperative Extension Service
Abstract
Synovex-S (SS) and STEER-oid (SO) were compared in a 122-d finishing study. No differences were observed over the entire study for animal performance or carcass traits. However, in the final period (d 91-122), steers implanted with SO gained 8.4% faster (P=.17) and 8.7% more efficiently (P=.10) than steers implanted with SS, suggesting that estradiol payout in this period was less diminished for SO implants. The importance of this finding is unknown, because it is generally recommended that steers fed for longer periods of time be reimplanted midway through the finishing period to maintain maximal implant response.
Description
Keywords
Beef, Implant, Estradiol comparison, Feedlot, Cattle