<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
dc.contributor.authorBell, Timmy
dc.date.accessioned2026-11-16T18:57:42Z
dc.date.graduationmonthDecember
dc.date.issued2026
dc.description.abstractThis thesis evaluated CaseMetrology, an embedded computer-vision system developed for static dimensional measurement of cartridge-case overall length (OAL). The formal study was limited to overall length and used a frozen cohort of 60 specimens, an independent manual reference process, and three independently randomized computer-vision placements per specimen for each prospective system configuration. The original V1 configuration used a principal component analysis (PCA) based estimator and established the prospective baseline. It achieved 100 percent measurement availability but met only one of six quantitative performance criteria. Its ninety-fifth percentile pairwise repositioning difference was 0.004831 inch, indicating substantial presentation-dependent variability. Subsequent engineering work investigated acquisition stability, fixture behavior, estimator design, and physical presentation. The final V3 configuration combined controlled specimen presentation with a frozen Endface-Hybrid estimator and was prospectively evaluated after configuration freeze. V3 again achieved 100 percent availability. At the specimen level, mean bias was negative 0.000435 inch, mean absolute error was 0.001517 inch, root mean squared error was 0.001794 inch, the nearest-rank ninety-fifth percentile absolute error was 0.003170 inch, and the maximum absolute error was 0.003913 inch. The ninety-fifth percentile pairwise repositioning difference was 0.000633 inch. This approximately 86.9 percent V1-to-V3 reduction reflects changes in both the estimator and physical presentation, so it cannot be attributed to presentation alone. V3 met five of the six retained quantitative criteria. The only unmet criterion was the ninety-fifth percentile absolute error target of 0.0030 inch. Under the unguarded specification rule, V3 produced one false pass and three false fails. The results demonstrate that repeated presentation stability and absolute agreement with the manual reference were distinct properties of the measurement system. The large improvement in repositioning did not eliminate residual specimen-level disagreement near the specification boundaries. A post-validation guard-band analysis showed that guarded decision logic could reduce observed false pass behavior within the study cohort, but those findings were retrospective and were not validated as a production decision rule. The completed research supports further development of CaseMetrology as a controlled static dimensional screening architecture. It does not establish the prototype as a replacement for precision reference metrology, a production-ready inline inspection system, or an unconditional final-acceptance device across the full specification interval.
dc.description.advisorMichael J. Pritchard
dc.description.degreeMaster of Science
dc.description.departmentCollege of Technology and Aviation
dc.description.levelMasters
dc.identifier.urihttps://hdl.handle.net/2097/47516
dc.language.isoen_US
dc.subjectComputer Vision
dc.subjectNon-Contact Measurement
dc.titleEngineering evaluation of an embedded computer-vision system for static dimensional screening of cartridge-case overall length
dc.typeThesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TimmyBell2026.pdf
Size:
1.65 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.65 KB
Format:
Item-specific license agreed upon to submission
Description: