Performance of lactating dairy cattle in three different cooling systems

dc.citation.epage15en_US
dc.citation.spage12en_US
dc.contributor.authorMeyer, M. J.
dc.contributor.authorSmith, John F., 1962-
dc.contributor.authorHarner, Joseph P.
dc.contributor.authorTitgemeyer, Evan C.
dc.contributor.authorShirley, John E.
dc.contributor.authoreidjfsmithen_US
dc.contributor.authoreidjharneren_US
dc.contributor.authoreidjshirleyen_US
dc.contributor.authoreidetitgemeen_US
dc.date.accessioned2011-05-04T14:45:03Z
dc.date.available2011-05-04T14:45:03Z
dc.date.issued2011-05-04
dc.date.published1998en_US
dc.description.abstractNinety-six Holstein multiple-lactation cows averaging 115 days in milk (DIM) and 60 Holstein first-lactation cows averaging 97 DIM at the initiation of a 10-wk study between June 10 and August 22, 1998 were used to evaluate the effectiveness of three different cooling systems. Thirty-two multiparous cows and 20 first-lactation cows were assigned to each of three pens that contained different cooling systems. The three cooling systems consisted of : 1) a single row of 36-inch fans, spaced at 24-ft intervals over the freestalls and over the feed row, 2) 56-inch ceiling fans spaced at 12-ft intervals over the freestalls, and 3) polytube longitudinal cooling over the freestalls. Each of the three cooling systems utilized similar sprinkler systems located over the feed line. Dry matter intake, respiration rates, milk production, and body condition scores were measured. Cows cooled with overhead 36-inch fans produced more milk and had lower respiration rates than those cooled with other methods. The cows cooled with ceiling fans tended to produce more milk than those cooled via the polytube. Dry matter intake also tended to be greater for cows cooled by overhead 36-inch fans.en_US
dc.description.conferenceDairy Day, 1998, Kansas State University, Manhattan, KS, 1998
dc.identifier.urihttp://hdl.handle.net/2097/8601
dc.publisherKansas Agricultural Experiment Station and Cooperative Extension Service.en_US
dc.relation.isPartOfDairy Day, 1998en_US
dc.relation.isPartOfKansas Agricultural Experiment Station contribution; no. 99-158-Sen_US
dc.relation.isPartOfReport of progress (Kansas Agricultural Experiment Station and Cooperative Extension Service); 821en_US
dc.subjectHeat stressen_US
dc.subjectDairyen_US
dc.subjectMilk productionen_US
dc.subjectCoolingen_US
dc.titlePerformance of lactating dairy cattle in three different cooling systemsen_US
dc.typeConference paperen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
DairyDay1998pg12-15.pdf
Size:
24.31 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections