dc.description.abstractMicrogrids with distributed generators have changed how protection and control systems are designed. Protection systems in conventional U.S. distribution systems are radial with the assumption that current flows always from the utility source to the end user. However, in a microgrid with distributed generators, currents along power lines do not always flow in one direction. Therefore, protection systems must be adapted to different circuit paths depending on distributed generator sites in the microgrid and maximum fuse ampere ratings on busses. Adaptive overcurrent protection focuses on objectives and constraints based on operation, maximum load demand, equipment, and utility service limitations. Adaptive overcurrent protection was designed to protect the power lines and bus feeders of the microgrid with distributed generators by coordinating fuses and relays in the microgrid. Adaptive overcurrent protection was based on the relay setting group and protection logic methods. Non-real-time simulator (NRTS) and real-time simulator (RTS) experiments were performed with computer-based simulators. Tests with two relays in the loop proved that primary relays tripped faster than backup relays for selectivity coordination in the adaptive overcurrent protection system. Relay test results from tripping and non-tripping tests showed that adaptive inverse time overcurrent protection achieved selectivity, speed, and reliability. The RTS and NRTS with two relays in the loop techniques were described and compared in this work. The author was the first graduate student to implement real-time simulation with two relays in the loop at the Burns & McDonnell - K-State Smart Grid Laboratory. The RTS experimental circuit and project are detailed in this work so other graduate students can apply this technique with relays in the loop in smart grid research areas such as phasor measurement units, adaptive protection, communication, and cyber security applications.en_US
dc.description.advisorAnil Pahwaen_US
dc.description.advisorNoel N. Schulzen_US
dc.description.degreeDoctor of Philosophyen_US
dc.description.departmentElectrical and Computer Engineeringen_US
dc.description.levelDoctoralen_US
dc.description.sponsorshipElectrical Power Affiliates Program (EPAP), College of Engineering, Kansas State Universityen_US
dc.identifier.urihttp://hdl.handle.net/2097/20537
dc.language.isoen_USen_US
dc.publisherKansas State Universityen
dc.subjectAdaptive protectionen_US
dc.subjectRelay test systemsen_US
dc.subjectReal-time simulator with relays-in-the-loopen_US
dc.subjectPower system protectionen_US
dc.subjectMicrogrid with distributed generatorsen_US
dc.subjectSmart grid laben_US
dc.subject.umiElectrical Engineering (0544)en_US
dc.titleRelay in the loop test procedures for adaptive overcurrent protectionen_US
dc.typeDissertationen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
EmilioPiesciorovsky2015.pdf
Size:
42.86 MB
Format:
Adobe Portable Document Format
Description:
Thesis Dissertation
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: