Responses of lactating holstein cows to low-pressure soaking or high-pressure misting during heat stress

dc.citation.epage31en_US
dc.citation.spage26en_US
dc.contributor.authorHarner, Joseph P.
dc.contributor.authorSmith, John F., 1962-
dc.contributor.authorMiller, W.F.
dc.contributor.authorCvetkovic, B.
dc.contributor.authorBrouk, Michael J.
dc.contributor.authoreidmbrouken_US
dc.contributor.authoreidjharneren_US
dc.contributor.authoreidjfsmithen_US
dc.date.accessioned2010-12-01T22:38:44Z
dc.date.available2010-12-01T22:38:44Z
dc.date.issued2010-12-01
dc.date.published2004en_US
dc.description.abstractLactating dairy cattle were used to evaluate three different cooling systems. Eight cows were arranged in a replicated Latinsquare design and assigned to each of four treatments. Treatments were control, lowpressure soaking (LPS), high-pressure misting with 1.7 gallons per minute of water (HP-1.7), or high-pressure misting with 3.4 gallons per minute of water (HP-3.4). Cows were allowed to become heat stressed in a free-stall facility, and then were moved to a tie-stall barn for 2 hours of observations during four hot and humid afternoons. Respiration rates declined when heat abatement systems were used. Respiration rates at the end of the observation period were reduced by 20, 36, and 48% for HP-1.7, HP-3.4, and LPS, respectively. Rearudder skin surface temperature was reduced at a faster rate under the HP-4 treatment than with LPS, but the two treatments did not differ in final rear-udder skin surface temperature or vaginal temperature. The HP-3.4 treatment used the greatest amount of water during the 2-hour testing period. The result was a combination of air-cooling and soaking. Results indicated that a combination of air cooling and soaking may result in faster reduction of surface temperature. When only air cooling was used (HP-1.7), heat stress was reduced, but it was less effective than either LPS or HP-3.4. Use of a low-pressure soaking system is superior to high-pressure misting unless cattle become soaked by the high-pressure system.en_US
dc.description.conferenceDairy Day, 2004, Kansas State University, Manhattan, KS, 2004
dc.identifier.urihttp://hdl.handle.net/2097/6743
dc.publisherKansas State University. Agricultural Experiment Station and Cooperative Extension Serviceen_US
dc.relation.isPartOfDairy Day, 2004en_US
dc.relation.isPartOfKansas Agricultural Experiment Station contribution; no. 05-112-Sen_US
dc.relation.isPartOfReport of progress (Kansas State University. Agricultural Experiment Station and Cooperative Extension Service); 941en_US
dc.subjectDairyen_US
dc.subjectHeat stress abatementen_US
dc.subjectCow comforten_US
dc.subjectCow coolingen_US
dc.titleResponses of lactating holstein cows to low-pressure soaking or high-pressure misting during heat stressen_US
dc.typeConference paperen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
DairyDay2004pg26-31.pdf
Size:
51.62 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections