Wireless reflectance pulse oximeter design and photoplethysmographic signal processing

K-REx Repository

Show simple item record

dc.contributor.author Li, Kejia
dc.date.accessioned 2010-05-11T18:10:40Z
dc.date.available 2010-05-11T18:10:40Z
dc.date.issued 2010-05-11T18:10:40Z
dc.identifier.uri http://hdl.handle.net/2097/4143
dc.description.abstract Pulse oximetry, a noninvasive circulatory system monitoring technique, has been widely adopted in clinical and homecare applications for the determination of heart rate and blood oxygen saturation, where measurement locations are typically limited to fingertips and earlobes. Prior research indicates a variety of additional clinical parameters that can be derived from a photoplethysmogram (PPG), the fundamental time-domain signal yielded by a pulse oximeter sensor. The gap between this research potential and practical device applications can be decreased by improvements in device design (e.g., sensor performance and geometry, sampling fidelity and reliability, etc.) and PPG signal processing. This thesis documents research focused on a novel pulse oximeter design and the accompanying PPG signal processing and interpretation. The filter-free reflectance design adopted in the module supplements new methods for signal sampling, control, and processing, with a goal to acquire high-fidelity raw data that can provide additional physiologic data for state-of-health analyses. Effective approaches are also employed to improve signal stability and quality, including shift-resistant baseline control, an anti-aliasing sampling frequency, light emitting diode intensity autoregulation, signal saturation inhibition, etc. MATLAB interfaces provide data visualization and processing for multiple applications. A feature detection algorithm (decision-making rule set) is presented as the latest application, which brings the element of intelligence into the pulse oximeter design by enabling onboard signal quality verification. Two versions of the reflectance sensor were designed, built, calibrated, and utilized in data acquisition work. Raw data, which are composed of four channels of signals at a 240 Hz sampling rate and a 12-bit precision, successfully stream to a personal computer via a serial connection or wireless link. Due to the optimized large-area sensor and the intensity autoregulation mechanism, PPG signal acquisition from measurement sites other than fingertips and earlobes, e.g., the wrist, become viable and retain signal quality, e.g., signal-to-noise ratio. With appropriate thresholds, the feature detection algorithm can successfully indicate motion occurrence, signal saturation, and signal quality level. Overall, the experimental results from a variety of subjects and body locations in multiple applications demonstrate high quality PPGs, prototype reliability, and prospects for further research value. en_US
dc.description.sponsorship National Science Foundation en_US
dc.language.iso en_US en_US
dc.publisher Kansas State University en
dc.subject Pulse oximeter en_US
dc.subject Photoplethysmogram en_US
dc.subject Feature detection en_US
dc.title Wireless reflectance pulse oximeter design and photoplethysmographic signal processing en_US
dc.type Thesis en_US
dc.description.degree Master of Science en_US
dc.description.level Masters en_US
dc.description.department Department of Electrical and Computer Engineering en_US
dc.description.advisor Steven Warren en_US
dc.subject.umi Engineering, Biomedical (0541) en_US
dc.subject.umi Engineering, Electronics and Electrical (0544) en_US
dc.date.published 2010 en_US
dc.date.graduationmonth May en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search K-REx


Advanced Search

Browse

My Account

Statistics








Center for the

Advancement of Digital

Scholarship

cads@k-state.edu