dc.description.abstract An experimental program was conducted at Kansas State University (KSU) to evaluate the bond characteristics of prestressing wires and strands used in the manufacture of pretensioned concrete railroad ties. Un-tensioned pullout tests were conducted using both concrete and mortar mediums. The effect of prestressing steel surface condition on bond was evaluated by testing the bond in both the as-received and cleaned condition. A pullout test was developed (and subsequently adopted as ASTM A1096) that can be used to determine the bond quality of prestressing wires that are are in pretensioned concrete members. The pullout test specimens consist of a 4 in. outer-diameter tube with a total length of 8 in. and a steel plate welded to the tube bottom. An un-tensioned wire is held concentrically in the tube while a sand-cement mortar mixture is placed and allowed to cure. Specimens are tested when compressive strength of the mortar is between 4500 and 5000 psi. Pullout test results had excellent correlation with transfer lengths of similar wires when used to manufacture pretensioned concrete railroad ties.
dc.publisher Rural Railroad Safety Center, Kansas State University.
dc.rights This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
dc.rights.uri https://rightsstatements.org/vocab/InC/1.0/
dc.subject ASTM A1096
dc.subject Wire Bond
dc.subject Un-Tensioned Pullout Tests
dc.subject Bond Slip
dc.subject Railroad Ties
dc.subject Prestressed Concrete
dc.title Development of Un-Tensioned Pullout Tests to Determine the Bond Quality of Prestressing Reinforcements Used in Pretensioned Concrete Railroad Ties
dc.type Text
dc.date.published 2021
dc.description.version Article: Version of Record


Files in this item

This item appears in the following Collection(s)

Show simple item record

This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s). Except where otherwise noted, the use of this item is bound by the following: This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).

Search K-REx


Advanced Search

Browse

My Account

Statistics








Center for the

Advancement of Digital

Scholarship

cads@k-state.edu