⁶Li-based suspended foil microstrip neutron detectors

K-REx Repository

Show simple item record

dc.contributor.author Edwards, Nathaniel Scott
dc.date.accessioned 2018-08-10T18:24:16Z
dc.date.available 2018-08-10T18:24:16Z
dc.date.issued 2018-08-01 en_US
dc.identifier.uri http://hdl.handle.net/2097/39131
dc.description.abstract The low natural abundance and supply shortage of ³He has resulted in an increase in the cost of ³He. The increase in cost of ³He proportional counters has motived the development of low cost, high efficiency, low gamma-ray sensitivity alternative technologies. A recently developed alternative technology is the ⁶Li-based suspended foil microstrip neutron detector (SFMND) that combines the neutron-conversion and gamma-ray discrimination capabilities of ⁶Li foils with the mechanical robustness and electrical capabilities of microstrip electrodes. SFMNDs differ from Li-foil multi-wire proportional counters because the anode wires are replaced by a single microstrip electrode that improves the mechanical robustness, reduces the microphonic sensitivity, and allows for more ⁶Li foils to be incorporated within a smaller form factor. The first-ever SFMNDs containing one and five 96%-enriched, 75-µm thick ⁶Li foils were fabricated using a silicon microstrip electrode. Neutron-sensitivity testing was performed yielding measured intrinsic thermal-neutron detection efficiencies, εth, of 4.02 ± 0.04% and 14.58 ± 0.11%, respectively. High electrode capacitance and gain instability were exhibited by the silicon microstrip electrode during neutron-sensitivity testing that led to the search for an electrically-stable microstrip-electrode substrate. Schott Borofloat® 33 glass was identified as an electrically-stable substrate and microstrip electrodes were fabricated and characterized. The Schott Borofloat® 33 microstrip electrodes were electrically-stable for a minimum duration of time of approximately 23 hours and had capacitances over an order of magnitude less than the identically sized silicon microstrip electrodes. One- and five-foil SFMNDs were fabricated with a Schott Borofloat® 33 microstrip electrode. Using 96%-enriched, 75-µm thick ⁶Li foils, the one- and five-foil devices had maximum measured εth of 12.58 ± 0.15% and 29.75 ± 0.26%, respectively, with measured gamma-ray rejection ratios of 6.46 x 10⁻⁵ ± 4.32 x 10⁻⁷ and 7.96 x 10-5 ± 4.65 x 10-7 for a ¹³⁷Cs exposure rate of 50 mR hr⁻¹. Devices containing one, five, ten, and twenty 96%-enriched, 75-µm thick ⁶Li foils were simulated using MCNP6 and are theoretically capable of having εth of 18.36%, 54.08%, 65.43%, and 68.36%, respectively. The deviation between measured and simulated εth is suspected to occur due to the electric field strength distribution, electron attachment, microstrip-electrode capacitance, or any combination thereof and solutions for each of these suspected concerns are described. en_US
dc.language.iso en_US en_US
dc.subject Neutron detection en_US
dc.subject Radiation detection en_US
dc.subject Microstrip electrodes en_US
dc.subject Lithium foil en_US
dc.subject Device characterization en_US
dc.subject Gas-filled neutron detector en_US
dc.title ⁶Li-based suspended foil microstrip neutron detectors en_US
dc.type Dissertation en_US
dc.description.degree Doctor of Philosophy en_US
dc.description.level Doctoral en_US
dc.description.department Department of Mechanical and Nuclear Engineering en_US
dc.description.advisor Douglas S. McGregor en_US
dc.date.published 2018 en_US
dc.date.graduationmonth August en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search K-REx


Advanced Search

Browse

My Account

Statistics








Center for the

Advancement of Digital

Scholarship

118 Hale Library

Manhattan KS 66506


(785) 532-7444

cads@k-state.edu