A comparison of Reduced Beam Section moment connection and Kaiser Bolted Bracket® moment connections in steel Special Moment Frames

dc.contributor.authorJohnson, Curtis Mathias
dc.date.accessioned2017-08-10T19:32:06Z
dc.date.available2017-08-10T19:32:06Z
dc.date.graduationmonthAugusten_US
dc.date.issued2017-08-01en_US
dc.date.published2017en_US
dc.description.abstractOf seismic steel lateral force resisting systems in practice today, the Moment Frame has most diverse connection types. Special Moment frames resist lateral loads through energy dissipation of the inelastic deformation of the beam members. The 1994 Northridge earthquake proved that the standard for welded beam-column connections were not sufficient to prevent damage to the connection or failure of the connection. Through numerous studies, new methods and standards for Special Moment Frame connections are presented in the Seismic Design Manual 2nd Edition to promote energy dissipation away from the beam-column connection. A common type of SMF is the Reduce Beams Section (RBS). To encourage inelastic deformation away from the beam-column connection, the beam flange’s dimensions are reduced a distance away from the beam-column connection; making the member “weaker” at that specific location dictating where the plastic hinging will occur during a seismic event. The reduction is usually taken in a semi-circular pattern. Another type of SMF connection is the Kaiser Bolted Bracket® (KBB) which consists of brackets that stiffen the beam-column connection. KBB connections are similar to RBS connections as the stiffness is higher near the connection and lower away from the connection. Instead of reducing the beam’s sectional properties, KBB uses a bracket to stiffen the connection. The building used in this parametric study is a 4-story office building. This thesis reports the results of the parametric study by comparing two SMF connections: Reduced Beam Section and Kaiser Bolted Brackets. This parametric study includes results from three Seismic Design Categories; B, C, and D, and the use of two different foundation connections; fixed and pinned. The purpose of this parametric study is to compare member sizes, member forces, and story drift. The results of Seismic Design Category D are discussed in depth in this thesis, while the results of Seismic Design Category B and C are provided in the Appendices.en_US
dc.description.advisorKimberly W. Krameren_US
dc.description.degreeMaster of Scienceen_US
dc.description.departmentDepartment of Architectural Engineering and Construction Scienceen_US
dc.description.levelMastersen_US
dc.identifier.urihttp://hdl.handle.net/2097/36233
dc.language.isoen_USen_US
dc.publisherKansas State Universityen
dc.subjectReduced Beam Sectionen_US
dc.subjectKaiser Bolted Bracketen_US
dc.subjectSpecial Moment Framesen_US
dc.subjectLateral Force Resisting Systemen_US
dc.subjectBeam-column connectionsen_US
dc.subjectSeismic designen_US
dc.titleA comparison of Reduced Beam Section moment connection and Kaiser Bolted Bracket® moment connections in steel Special Moment Framesen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CurtisJohnson2017.pdf
Size:
2.11 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: