Wireless reflectance pulse oximeter design and photoplethysmographic signal processing

dc.contributor.authorLi, Kejia
dc.date.accessioned2010-05-11T18:10:40Z
dc.date.available2010-05-11T18:10:40Z
dc.date.graduationmonthMayen_US
dc.date.issued2010-05-11T18:10:40Z
dc.date.published2010en_US
dc.description.abstractPulse oximetry, a noninvasive circulatory system monitoring technique, has been widely adopted in clinical and homecare applications for the determination of heart rate and blood oxygen saturation, where measurement locations are typically limited to fingertips and earlobes. Prior research indicates a variety of additional clinical parameters that can be derived from a photoplethysmogram (PPG), the fundamental time-domain signal yielded by a pulse oximeter sensor. The gap between this research potential and practical device applications can be decreased by improvements in device design (e.g., sensor performance and geometry, sampling fidelity and reliability, etc.) and PPG signal processing. This thesis documents research focused on a novel pulse oximeter design and the accompanying PPG signal processing and interpretation. The filter-free reflectance design adopted in the module supplements new methods for signal sampling, control, and processing, with a goal to acquire high-fidelity raw data that can provide additional physiologic data for state-of-health analyses. Effective approaches are also employed to improve signal stability and quality, including shift-resistant baseline control, an anti-aliasing sampling frequency, light emitting diode intensity autoregulation, signal saturation inhibition, etc. MATLAB interfaces provide data visualization and processing for multiple applications. A feature detection algorithm (decision-making rule set) is presented as the latest application, which brings the element of intelligence into the pulse oximeter design by enabling onboard signal quality verification. Two versions of the reflectance sensor were designed, built, calibrated, and utilized in data acquisition work. Raw data, which are composed of four channels of signals at a 240 Hz sampling rate and a 12-bit precision, successfully stream to a personal computer via a serial connection or wireless link. Due to the optimized large-area sensor and the intensity autoregulation mechanism, PPG signal acquisition from measurement sites other than fingertips and earlobes, e.g., the wrist, become viable and retain signal quality, e.g., signal-to-noise ratio. With appropriate thresholds, the feature detection algorithm can successfully indicate motion occurrence, signal saturation, and signal quality level. Overall, the experimental results from a variety of subjects and body locations in multiple applications demonstrate high quality PPGs, prototype reliability, and prospects for further research value.en_US
dc.description.advisorSteven Warrenen_US
dc.description.degreeMaster of Scienceen_US
dc.description.departmentDepartment of Electrical and Computer Engineeringen_US
dc.description.levelMastersen_US
dc.description.sponsorshipNational Science Foundationen_US
dc.identifier.urihttp://hdl.handle.net/2097/4143
dc.language.isoen_USen_US
dc.publisherKansas State Universityen
dc.subjectPulse oximeteren_US
dc.subjectPhotoplethysmogramen_US
dc.subjectFeature detectionen_US
dc.subject.umiEngineering, Biomedical (0541)en_US
dc.subject.umiEngineering, Electronics and Electrical (0544)en_US
dc.titleWireless reflectance pulse oximeter design and photoplethysmographic signal processingen_US
dc.typeThesisen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
KejiaLi2010.pdf
Size:
8.84 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description: