Investigations of a printed circuit heat exchanger for supercritical CO2 and water

dc.contributor.authorSong, Hoseok
dc.date.accessioned2007-07-11T16:34:24Z
dc.date.available2007-07-11T16:34:24Z
dc.date.graduationmonthAugusten
dc.date.issued2007-07-11T16:34:24Z
dc.date.published2007en
dc.description.abstractIn the STAR-LM (Secure Transportable Autonomous Reactor-Liquid Metal) reactor concept developed at Argonne National Laboratory (ANL), a supercritical CO2 (S-CO2) Brayton cycle is used as the power conversion system because it features advantages such as a higher efficiency due to less compressive work, and competitive cost due to a reduced complexity and size. From the components of the cycle, high performance of both the recuperator and precooler has a large influence on the overall cycle efficiency and plant economy. One attractive option for optimizing the performance of the cycle is to use an high efficiency heat exchanger such as the Printed Circuit Heat Exchanger (PCHE) manufactured by Heatric. The PCHE is a compact heat exchanger with high effectiveness, wide operating range, enhanced safety, and low cost. PCHEs are used in various industrial applications, but are relatively new to the nuclear industry. In this study, performance testing of a PCHE using supercritical CO2 and water as heat transfer media were performed at ANL. The heat transfer characteristics of the PCHE under operating conditions of the STAR_LM precooler were investigated. The S-CO2 , defined the “hot-side”, had its outlet condition near the pseudocritical point at 7.5MPa (~31-32 C). We found that of all the thermophysical properties undergoing rapid change near the critical point, heat transfer for S-CO2 is strongly correlated with the specific heat of CO2. Additional experiments performed with different bulk temperatures and pressures on the hot side also supported this conclusion. We proposed plotting the heat transfer results, (Nu2 + Pr2/3) versus (RePr4/3), based on an order-of-magnitude analysis, to reveal the close proximity of the outlet to pseudocritical conditions. In order to check the experimental results, a nodal model of a segmented PCHE using a traditional log-mean temperature difference method was developed. This approach provided the temperature distribution along the heat exchanger. Additionally a CFD simulation (FLUENT) of a 4-layer, zig-zag channeled PCHE was developed. Comparison of the simulation and LMTD nodal model revealed that indeed specific heat strongly influenced the heat transfer.en
dc.description.advisorAkira T. Tokuhiroen
dc.description.degreeMaster of Scienceen
dc.description.departmentDepartment of Mechanical and Nuclear Engineeringen
dc.description.levelMastersen
dc.description.sponsorshipThe Department of Energy under the Nuclear Energy Research Initiativeen
dc.identifier.urihttp://hdl.handle.net/2097/346
dc.language.isoen_USen
dc.publisherKansas State Universityen
dc.subjectCompact heat exchangeren
dc.subjectSupercriticalen
dc.subject.umiEngineering, Mechanical (0548)en
dc.titleInvestigations of a printed circuit heat exchanger for supercritical CO2 and wateren
dc.typeThesisen

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
HoseokSong2007.pdf
Size:
2.99 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.69 KB
Format:
Item-specific license agreed upon to submission
Description: