Experimental analysis of particulate movement in a large Eddy Simulation Chamber

K-REx Repository

Show simple item record

dc.contributor.author Padilla, Angelina Marianna
dc.date.accessioned 2008-05-15T21:13:12Z
dc.date.available 2008-05-15T21:13:12Z
dc.date.issued 2008-05-15T21:13:12Z
dc.identifier.uri http://hdl.handle.net/2097/786
dc.description.abstract Millions of people travel by commercial aircraft each year. The close proximity of passengers aboard an airplane leads to one of the primary reasons that air quality in an aircraft cabin is of interest. In recent years there have been multiple reported instances of people contracting illnesses after being aboard an aircraft for an extended period of time. In order to better understand air quality in an aircraft cabin, an experimental study of particulate transport in a half cabin model of a Boeing 767 was performed. In the study, both 3[Mu]m and 10[Mu]m particles were tested separately by injecting them into the cabin through a vertical tube, 609.6 mm (24 in) above the floor, at a single location on the centerline of the half cabin test section. Resulting particulate concentrations were measured at five locations along the centerline of the half cabin test section. It was found that for the 3[Mu]m particles, the normalized concentration was about one for all of the locations except directly above the injection site. Therefore, the concentrations were approximately the same as the well-mixed concentration, where the well-mixed concentration is the concentration in the test cabin if the test cabin is uniformly mixed. For the same test conditions, the normalized concentrations for the 10[Mu]m particles were well below one, around 0.1. Several more concentration measurements using the 10[Mu]m particles were taken at the same five locations, both on and off the centerline, and for different particle injection and cabin pressure conditions. The concentration results using a diffuser cone to inject the 10[Mu]m particles into the test cabin and a neutral cabin pressure were higher than the results found using the straight injection tube, but they were not very repeatable. After pressurizing the cabin to slightly above ambient pressure and using the diffuser cone, the resulting average normalized particle concentrations along the centerline were found to be between 0.4 and 1.5 and repeatable within the estimated measurement uncertainty. Therefore, it appears that the 3[Mu]m particles follow the airflow in the test cabin well, but it is not clear if the 10[Mu]m particles do as well. en
dc.description.sponsorship The Boeing Company en
dc.language.iso en_US en
dc.publisher Kansas State University en
dc.subject Particle transport en
dc.subject Indoor particulate movement en
dc.subject Ventinlated chamber en
dc.title Experimental analysis of particulate movement in a large Eddy Simulation Chamber en
dc.type Thesis en
dc.description.degree Master of Science en
dc.description.level Masters en
dc.description.department Department of Mechanical and Nuclear Engineering en
dc.description.advisor Mohammad H. Hosni en
dc.subject.umi Engineering, Aerospace (0538) en
dc.subject.umi Engineering, Environmental (0775) en
dc.date.published 2008 en
dc.date.graduationmonth May en


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search K-REx


Advanced Search

Browse

My Account

Statistics








Center for the

Advancement of Digital

Scholarship

118 Hale Library

Manhattan KS 66506


(785) 532-7444

cads@k-state.edu