Applying the cognitive reliability and error analysis method to reduce catheter associated urinary tract infections

Date

2016-05-01

Journal Title

Journal ISSN

Volume Title

Publisher

Kansas State University

Abstract

Catheter associated urinary tract infections (CAUTIs) are a source of concern in the healthcare industry because they occur more frequently than other healthcare associated infections and the rates of CAUTI have not improved in recent years. The use of urinary catheters is common among patients; between 15 and 25 percent of all hospital patients will use a urinary catheter at some point during their hospitalization (CDC, 2016). The prevalence of urinary catheters in hospitalized patients and high CAUTI occurrence rates led to the application of human factors engineering to develop a tool to help hospitals reduce CAUTI rates. Human reliability analysis techniques are methods used by human factors engineers to quantify the probability of human error in a system. A human error during a catheter insertion has the opportunity to introduce bacteria into the patient’s system and cause a CAUTI; therefore, human reliability analysis techniques can be applied to catheter insertions to determine the likelihood of a human error. A comparison of three human reliability analysis techniques led to the selection of the Cognitive Reliability and Error Analysis Method (CREAM). To predict a patient’s probability of developing a CAUTI, the human error probability found from CREAM is incorporated with several health factors that affect the patient’s risk of developing CAUTI. These health factors include gender, duration, diabetes, and a patient’s use of antibiotics, and were incorporated with the probability of human error using fuzzy logic. Membership functions were developed for each of the health factors and the probability of human error, and the centroid defuzzification method is used to find a crisp value for the probability of a patient developing CAUTI. Hospitals that implement this tool can choose risk levels for CAUTI that places the patient into one of three zones: green, yellow, or red. The placement into the zones depends on the probability of developing a CAUTI. The tool also provides specific best practice interventions for each of the zones.

Description

Keywords

Cognitive reliability and error analysis method, Catheter associated urinary tract infection, Fuzzy logic, Human reliability analysis

Graduation Month

May

Degree

Master of Science

Department

Department of Industrial & Manufacturing Systems Engineering

Major Professor

Malgorzata Rys

Date

2016

Type

Thesis

Citation